Sample project · read-only. Public Alberta data, with synthetic custody records that are marked where they appear.
Results and control examples are intentionally separate. Values in the matched-results register come directly from the public source. Standard, blank, duplicate, and review details are synthetic examples; CoreChain makes no technical interpretation of either.
Public source data
Matched laboratory result rows Each row is matched by original sample ID, drillhole, and interval. Reported values retain the source text, including less-than values.
Match Source assay Laboratory record Reported values Matched CC-DEMO-5739 Source sample 5739 AGS 6481367.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 Cr 82 ppm Li 54 ppm Pb 5 ppm V 114 ppm Zn 81 ppm Matched CC-DEMO-5739 Source sample 5739 AGS 6481467.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 Matched CC-DEMO-5739 Source sample 5739 AGS 6481567.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 As 9 ppm Ba 382 ppm Bi <5 ppm La 33 ppm Mn 213 ppm Nb 16 ppm Sb <5 ppm Sc 14 ppm Ta <5 ppm Y 23 ppm Zr 103 ppm Matched CC-DEMO-5739 Source sample 5739 AGS 6481667.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 Matched CC-DEMO-5739 Source sample 5739 AGS 6481767.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 Al 8.51 % Ca 1.27 % Fe 9.27 % K 2.72 % Mg 0.89 % Na 0.15 % Ti 0.4 % Matched CC-DEMO-5739 Source sample 5739 AGS 6481867.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 Matched CC-DEMO-5739 Source sample 5739 AGS 6481967.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 Cd <1.0 ppm Co 26 ppm Cu 19 ppm Mo <1 ppm Ni 40 ppm Sr 99 ppm Matched CC-DEMO-5739 Source sample 5739 AGS 6482067.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29 Matched CC-DEMO-5739 Source sample 5739 AGS 6482167.25 to 68.25 m Bondar-Clegg & Company Ltd. ICP; certificate 2001-11-29
QA/QC control register Synthetic examples only. No acceptance rule is implied.
Synthetic Standard Example control response recorded as 1.48 units.
Example review range: 1.10 to 1.40 units. Flagged for review
Synthetic Blank Example blank recorded below its example reporting threshold.
Example action: review only if the threshold is exceeded. No alert shown
Synthetic Field duplicate Example duplicate comparison was logged for reviewer context.
Example action: a qualified person sets the comparison rule. Review recorded
Synthetic review state
Review required Hold the demonstration control for qualified geologist review.
This is an example workflow state, not a technical acceptance decision or a universal QA/QC limit.